Quick Details:
Products Status:Stock
Transmission Rate:10/100/1000Mbps
Function:QoS
Communication Mode:Full-Duplex
Certification:RADIUS
Switch Capacity:2.56Tbps
Brand Name:H3C
Model Number:S6800-4C
Place of Origin:Guangdong, China
Warranty:1year
Dimensions (W x D x H):440*660*88.1mm
Packaging & Delivery:
Packaging Details:1.Anti-static bag for each hdd.
2.each goods use Foam buffer protect from friction
3.The goods be packed very well ,can ship to all over the world
Port: HongKong
Lead Time :
Quantity(Pieces) |
1 - 1 |
>1 |
Est. Time(days) |
30 |
To be negotiated |
Product Description:
Features
|
S6800-32Q
|
S6800-54QF
|
S6800-54QT
|
S6800-2C
|
S6800-4C
|
Dimensions
(W × D × H) |
440×660×43.6
|
440×400×44
|
440×460×44
|
440×660×44.2
|
440×660×88.1
|
Weight
|
≤13kg
|
≤13kg
|
≤13kg
|
≤16Kg
|
≤27Kg
|
Console port
|
Console :1; Mini USB Console: 1
|
||||
Flash/Memory
|
1GB/4GB
|
||||
Ethernet port
for management |
1
|
10M/100M/1000MBase-T: 1
SFP 1000Base-X: 1 |
1
|
1
|
|
USB port
|
1
|
||||
1/10G Base-T port
|
/
|
/
|
48
|
/
|
/
|
1/10G SFP+ port
|
/
|
48
|
/
|
/
|
/
|
QSFP port
|
32
|
6
|
6
|
2
|
/
|
QSFP28 port
|
/
|
||||
Module slot
|
/
|
2
|
4
|
||
Input Voltage –AC
|
Related voltage range: 100V to 240V AC, 50/60Hz Maximum voltage range: 90V to 290V AC
|
||||
Input Voltage –DC
|
Related voltage range: -38.4V to -72V DC
|
||||
Power module
|
Two
|
Four
|
|||
Fan
|
Two hot-swappable fan,
fan speed adjustable and wind invertible |
Three hot-swappable fan,
fan speed adjustable and wind invertible |
Five hot-swappable fan,
fan speed adjustable and wind invertible |
Two hot-swappable fan, fan
speed adjustable and wind invertible |
|
Power consumption
(idle) |
Single AC: 132W
Dual AC: 145W Single DC: 128W Dual DC: 142W |
PSR250-12A
PSR250-12A1: Single AC:65W Dual AC:71W PSR450-12A1: Single AC:68W Dual AC:79W PSR450-12D: Single DC:67W Dual DC:76W |
PSR450-12A1:
Single AC:103WDual AC:109W PSR450-12D: Single DC:107W Dual DC:113W |
Single AC: 95W
Dual AC: 110W Single DC: 91W Dual DC: 105W |
Dual AC: 135W
Three AC: 150W Four AC: 165W Dual DC: 131W Three DC: 145W Four DC: 155W |
Power consumption
(fully loaded) |
Single AC: 291W
Dual AC: 301W Single DC: 291W Dual DC: 299W |
PSR250-12A/PSR250-12A1:
Single AC:165W Dual AC:175W PSR450-12A1: Single AC:166W Dual AC:175W PSR450-12D: Single DC:166W Dual DC:171W |
PSR450-12A1:
Single AC:103W Dual AC:109W PSR450-12D: Single DC:107W Dual DC:113W |
Single AC:439W
Dual AC: 450W Single DC:443W Dual DC: 445W |
Dual AC: 827W
Three AC: 837W Four AC: 856W Dual DC: 823W Three DC: 825W Four DC: 828W |
Operating temperature
|
0℃~45℃
|
||||
Operating relative
humidity |
10%~90%
|
||||
Port Switching
Capacity |
2.56Tbps
|
1.44Tbps
|
1.44Tbps
|
1.44Tbps
|
2.56Tbps
|
Forwarding
performance |
1440Mpps
|
1080Mpps
|
1080Mpps
|
1080Mpps
|
1440Mpps |
Forwarding mode
|
Store-forward and cut-through
|
||||
Virtualization
|
Intelligent Resilient Framework 2 (IRF2)
Distributed device management Stacking through standard Ethernet port Local and remote stacking LACP, BFD, ARP and MAD based stack collision |
||||
Link aggregation
|
10GE port aggregation
40GE port aggregation Static aggregation, dynamic aggregation Link cross board aggregation, cross device link aggregation M-LAG |
||||
Data center features
|
VXLAN L2 switching
VXLAN L3 routing VXLAN VTEP MP-BGP+EVPN distributed control plane 802.1Qbb PFC, 802.1Qaz ETS, ECN FCoE and FC protocol stack FC/FCoE/Ethernet multiplexing ports TRILL TRILL & IRF SPB OpenFlow1.3.1 Netconf , Python Service chain Multiple OpenFlow controller |
||||
Jumbo Frame
|
√
|
||||
MAC address table
|
Static MAC address
Blackhole MAC address |
||||
VLAN
|
Port-based VLAN (4094)
Default VLAN |
||||
Traffic monitoring
|
sFlow
|
||||
DHCP
|
DHCP Server/Client
DHCP Snooping DHCP Relay DHCP Snooping option82/DHCP Relay option82 |
||||
ARP
|
Static table entry
Gratuitous ARP Dynamic ARP Inspection ARP anti-attack ARP source suppression ARP Detection function (check according to DHCP Snooping safety entry, 802.1x table entry or IP/MAC static binding table entry) |
||||
IPv4 routing
|
Static routing, RIP v1/2, OSPFv1/v2/v3, BGP, IS-IS
Equal-Cost Multi-Path routing (ECMP), VRRP, policy-based routing |
||||
IPv6 routing
|
RIPng, OSPF v3, IS-IS v6
BGP4 + for IPv6, VRRP, IPv6 routing strategy ND (Neighbor Discovery) PMTU ICMP v6, Telnet v6, SFTP v6, SNMP v6, BFD v6, VRRP v3 IPv6 Portal IPv6 tunnel |
||||
Multicast protocol
|
IGMP Snooping v2/v3
IGMP v1/v2/v3 PIM-DM/SM IPv6 PIM-DM/SM/SSM PIM, MSDP MLD Snooping Multicast policy |
||||
Zero configuration
|
Auto-config and Configure Rollback
|
||||
MPLS
|
MCE
MPLS VPN and VPLS |
||||
MSTP
|
STP/RSTP/MSTP
PVST+/RPVST+ STP Root Guard BPDU Guard |
||||
QoS/ACL
|
Flow control
Committed Access Rate (CAR) Eight output queues per port Flexible queue scheduling algorithm can be set based on port and queue, support SP, WRR, WFQ, SP + WRR, SP + WFQ and other models 802.1p and DSCP priority re-marking L2 (Layer 2) ~ L4 (Layer 4) packet filtering based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, port, protocol, and VLAN Traffic Classification Time range Weighted Random Early Detection (WRED) |
||||
Mirror
|
Flow Mirroring
N: 4 port mirroring Local and remote port mirroring |
||||
Security
|
Hierarchical user management and password protection
AAA authentication support RADIUS authentication HWTACACS SSH 2.0 IP + MAC + port binding IP Source Guard HTTPs SSL Public Key Infrastructure (PKI) |
||||
Firmware
upgrade |
Upgrade via the XModem, File Transfer Protocol (FTP)
and Trivial File Transfer Protocol (TFTP) |
||||
Management
and maintenance |
Configuration via CLI, Telnet, and Console port
Schedule job ISSU SNMP(Simple Network Management Protocol) H3C Intelligent Management Centre (iMC) System log Hierarchical alarm NTP Power, fan and temperature alarms Debug string output Ping, Tracert Track Telnet remote maintenance Copy switch files to and from a USB flash drive |
||||
EMC
|
FCC Part 15 Subpart B CLASS A
ICES-003 CLASS A VCCI CLASS A CISPR 32 CLASS A EN 55032 CLASS A AS/NZS CISPR32 CLASS A CISPR 24 EN 55024 EN 61000-3-2 EN 61000-3-3 ETSI EN 300 386 GB 9254 YD/T993 |
||||
Safety
|
UL 60950-1
CAN/CSA C22.2 No 60950-1 IEC 60950-1 EN 60950-1 AS/NZS 60950-1 FDA 21 CFR Subchapter J GB 4943.1 |
||||
Flexible port combination
As network bandwidth tremendously grows, 10GE adapters are increasingly common in servers. The need of delivering high forwarding
performance and providing more 10/40/100 GE expansion space has become essential.
H3C S6800-4C is built to cope with the need providing four module slots, and supporting high density 10G SFP+ fiber, 1/10G Base-T
copper and 40G QSFP+ flexible configuration combination. The S6800-4C can also support a maximum of 96 10G and 8 40G ports, or 32
40G ports and can even support 96 FC/FCoE/Ethernet universal ports through its flexible FC interface module.
H3C S6800-2C can support a maximum of 48 10G and 6 40G ports or 18 40G ports. Through its flexible FC interface module, S6800-2C
can even support 48 FC/FCoE/Ethernet universal ports.
For 100G uplink, the S6800-54HF/HT can support fixed 48 10G Base-X or Base-T and 6 100G QSFP28 ports.
For 40G uplink, the S6800-54QF/QT can support fixed 48 10G Base-X or Base-T and 6 40G QSFP28 ports.
S6800-32Q features 32*40G QSFP+ port, via 40G to 10G cable, supporting a maximum 104 10G ports.
Intelligent Resilient Framework 2 (IRF2)
H3C S6800 switch series is pre-built with Intelligent Resilient Framework 2 (IRF2). IRF2 provides the following benefits:
High scalability: With IRF2, plug-n-play device aggregation can be achieved by adding one or more switches into the IRF2 stack
and enabling IRF2 stacking on the new device. New devices can be managed with a single IP, and upgraded at the same time to reduce
network expansion cost.
High reliability: The IRF2 patented 1:N backup technology allows each slave device in the IRF2 stack to serve as the backup of
the master, creating control and data link redundancy, as well as uninterrupted layer-3 forwarding. This improves the reliability,
avoids unplanned business downtime and serves to improve overall performance. When the master device fails, traffic remains
uninterrupted.
Load balancing: IRF2 supports cross-device link aggregation, upstream and downstream can be connected to more than one physical
link, which creates another layer of network redundancy and boosts the network resource utilization.
Availability: H3C Implements IRF2 through standard Forty Gigabit Ethernet (40GE) or Ten Gigabit Ethernet (10GE) ports which
allocates bandwidth for business and application access and reasonably splits local traffic and upstream traffic. IRF2 rules can
not only be obeyed within and across the rack, but also across the LAN.
Data Center-Oriented Features
FCoE (Fiber Channel over Ethernet) technology leverages Ethernet packet to carry FC packets. This means FC SAN and Ethernet LAN
network can share the same network infrastructure, which is a good solution to solve the problems of coexistence between different
types of network. S6800 switch series supports full FCoE and FC protocol stack. All downstream SFP + ports can be switched to FC
port to interoperate with FC SAN. As the FC SAN and Ethernet network are fully integrated, the entire network infrastructure is
greatly simplified.
TRILL (Transparent Interconnection of Lots of Links) is an innovative technology that changes the traditional way to build data
center networks. It incorporates the benefits of layer 3 routing technology, such as stable, scalable and high performance into an
adaptable, but limited scope of layer 2 switching network. The end result is flexible, extensible, high-performance layer 2
network architecture. By using TRILL technology, S6800 switch series becomes the ideal choice to build a large, high-performance,
and scalable cloud data center networks that support live virtual machines.
SDN (Software Defined Network) is an innovative network architecture that simplifies network management and reduces maintenance
complexity. This is accomplished by separating network control layer and network forwarding layer through OpenFlow. More
importantly, it implements flexible network flow control and provides a well-defined network platform for core network application
and innovation.
H3C S6800 switch series supports DCB (Data Center Bridging), ISSU (In-service Software Upgrade), OAM (Operations, Administration
and Maintenance) and EEE (Energy-Efficient Ethernet) . It fully meets the high performance data center requirements, and is easy
to manage with green energy consumption.
H3C S6800 switch series supports VXLAN (Virtual Extensible LAN), VXLAN uses a MAC-in-UDP encapsulation method where the original
Layer 2 package is added a VXLAN header, and is then placed in a UDP-IP packet. With the help of MAC-in-UDP encapsulation, VXLAN
tunnels Layer 2 network over Layer 3 network. This provides two major benefits, higher scalability of Layer 2 segmentation and
better utilization of available network paths.
H3C S6800 switch series supports MP-BGP EVPN (Multiprotocol Border Gateway Protocol Ethernet Virtual Private Network) uses
standard-based BGP protocol as the control plane for VXLAN overlay networks, providing BGP based VTEP auto peer discovery and
end-host reachability information distribution. MP-BGP EVPN delivers many benefits, such as eliminating traffic flooding, reducing
full mesh requirements between VTEPs via the introduction of BGP RR, achieving optimal flow based end to end load sharing and
more.
H3C S6800 switch series supports the intelligent caching technology. Its hardware implements intelligent distribution of traffic
load, while utilization ratio increases up to five times than traditional method. In addition, S6800 employs intelligent hardware
entry technology to achieve MAC/ARP/IP routing FIB table adjusts dynamically, and entry specification (such as MAC maximum up
288K) increased by 10 times compared with traditional switches. S6800 also supports intelligent hash technology. Under heavy
network traffic, it can significantly eliminate network polarization and load imbalances. S6800 switch series uses
high-performance multi-core CPU architecture and modular software operating platform to achieve greater flexibility when
scheduling tasks with different priorities.
Flexible choice of airflow
To cope with data center cooling aisle design, the H3C S6800 switch series comes with flexible airflow design, which features
bi-cooling aisles in the front and back. Users may also choose the direction of airflow (from front to back or vice versa) by
selecting a different fan tray.
Outstanding security control policies
H3C S6800 switch series supports AAA, RADIUS and user account based authentication, IP, MAC, VLAN, port-based user
identification, dynamic and static binding; when working with the H3C iMC platform, it can conduct real time management, instant
diagnosis and crackdown on illicit network behavior.
H3C S6800 switch series supports enhanced ACL control logic, which enables an enormous amount of in-port and out- port ACL, and
delegate VLAN based ACL. This simplifies user deployment process and avoids ACL resource wastage. S6800 switch series can also
take advantage of Unicast Reverse Path Forwarding (Unicast RPF). When the device receives a packet, it will perform the reverse
check to verify the source address from which the packets are supposedly originated, and will drop the packet if such path doesn’t
exist. This will curb the increasingly common originating address spoofing.
MACsec
H3C S6800 switch series supports hardware level encryption technology MACsec (802.1ae), which is an industry-standard security
technology that provides secure communication for all traffic on Ethernet links. Compared with traditional application based
software encryption technology, MACsec provides point to-point security on Ethernet links between directly connected nodes and is
capable of identifying and preventing most security threats.
Multiple Reliability
H3C S6800 switch series provides multiple reliability protection at both switch and link levels. With overcurrent, overvoltage,
and overheat protection, all models have a redundant pluggable power module, which enables flexible configuration of AC or DC
power modules based on actual needs. The entire switch supports fault detection and alarm for power supply and fan, allowing fan
speed to change to suit different ambient temperatures.
Excellent manageability
H3C S6800 switch series provides a rich management interface, including console, external network and USB. Management protocols
such as SNMPv1/v2/v3 are supported aside from iMC Management Console. The network administrator may activate control through CLI,
Web interface and TELNET which gives maximum flexibility in accessing and managing the device. The administrator may also choose
SSH2.0 and SSL encryption to shield the management session.
Packing & Delivery:
1. DHL / UPS / FedEx / TNT , Door-to-Door.
2. By Air or by Sea , for FCL; Airport/ Port receiving.
3. Customers Specifying Freight Forwarders or Negotiable Shipping Methods.
We will choose the best and safe packaging material to make sure your orders won't be
damaged during delivery.
Company Profie:
TFC is one-stop supplier for quality new, used and refurbished IT hardware. NMI buys, sells, leases, rents, consigns and trades
just about every product line including Sun, HP, IBM, Dell,Lenovo, storage equipment as NetApp and EMC, telecom equipment as
H3C,HUAWEI,CISCO,Juniper etc...